FREE STUDY NOTES · 2V0-13.25

Requirements, constraints, assumptions, risks and dependencies in VCF design

How to tell the five apart, what each obliges the architect to do, and worked classifications.

From Ultra Transcenders 2V0-13.25 by Tony Rough

Objective 1.3 and the candidate description expect you to separate five kinds of statement, because each one obliges the architect to do something different.

Term What it is What the architect must do
Requirement Something the solution must do or achieve Meet it; prove it in validation
Constraint A fixed limit on design choices, set outside the architect’s authority Design within it; record its effect
Assumption Something believed true but not yet proven Validate it; give it an owner and date
Risk An uncertain event that would harm the design’s goals Assess it; choose a response
Dependency Something the design relies on but does not control Confirm delivery; track it

Five quick tests separate them:

They are linked. An assumption that proves false becomes a risk, a new constraint or a changed requirement; until it is validated it is itself a risk. A dependency that might arrive late or not at all is a risk. A constraint often creates a risk: one data centre is a certainty, and the risk is what a site-wide outage would do.

Statement Classification Reason
The shop must be recoverable in another region after a regional disaster Business requirement Outcome the business needs
Only one data centre is available for three years Constraint Fixed limit on site choices
Existing Fibre Channel arrays must be reused Constraint Limits storage options
Workload growth stays under 20% a year Assumption Unproven; check capacity data
The network team will enable jumbo frames on overlay VLANs Assumption and dependency Unconfirmed; another team delivers it
Corporate DNS holds forward and reverse records for management components Dependency Required by VCF; run by another team
A rack power failure could stop the whole management cluster Risk Possible event with impact
The operations team may miss NSX training before go-live Risk Uncertain; hurts manageability
A stretched vSAN cluster needs a witness site independent of both data sites Dependency Third site the business must supply
Management budget covers four hosts at most Constraint Fixed limit on footprint
Management components need statically assigned IPv4 addresses Constraint VCF design requirement

Several rows are grounded in documented VCF facts. The Fibre Channel storage model can use existing arrays, but VCF’s automated workflows do not provision it and extra management tools are needed. Host and edge TEP VLANs need an MTU of at least 1700, with 9000 or larger recommended and configured end to end. The single-rack cluster model gives no protection against a rack failure. The vSAN stretched cluster model needs a third site, with no logical or physical dependency on either data site, to host the witness appliance.

The last row shows a subtlety. The VCF design guide labels some elements Design Requirement: required for VCF to operate, with no deviation permitted. Examples are statically assigned IPv4 addresses and host names, forward and reverse DNS records for all management components, and an internal NTP source for all management components. From the customer’s side these act as constraints on the design, and the DNS and NTP ones create dependencies on external services (Chapter 4: Prerequisites, external services and the physical network).

Common trap: Writing an unvalidated assumption into the requirements as fact, such as “the inter-site link is under 5 ms” - a vSAN stretched design depends on that figure, so it must stay an assumption with an owner until it is measured.

Common trap: Calling a constraint a risk - “only one data centre” is certain, not uncertain; record it as a constraint and record its consequence (a site-wide outage stops the fleet) as the risk.