FREE STUDY NOTES · 3V0-25.25

NSX load balancer vs Distributed Load Balancer vs Avi

What each VCF 9.0 load-balancing option supports, where it runs, and inline versus one-arm topology.

From Ultra Transcenders 3V0-25.25 by Tony Rough (coming December 2026)

VCF 9.0 has three load-balancing options with very different scope. The workload type usually decides between them.

NSX load balancer

GET /policy/api/v1/infra/lb-node-usage?node_path=<node-path>
Topology Load balancer in the traffic path Virtual server SNAT
Inline Yes, between client and server Not required, unless clients and servers are on segments of the same Tier-1
One-arm No; client and server can be anywhere Required, to force return traffic through the load balancer

In an all-VLAN design with a one-arm load balancer, overlay must still be configured on the Edge nodes. Edge nodes need at least one tunnel endpoint up to agree on active and standby roles.

Distributed load balancer

The Distributed Load Balancer runs on every ESX host and balances only east-west traffic. It is supported only for Kubernetes cluster IPs managed by the vSphere Supervisor (the page still uses the old name, vSphere with Kubernetes). Its objects are pushed by vCenter through the NSX API and cannot be created or changed in the NSX Manager UI. DFW must stay enabled for its workloads: disabling DFW globally or through the exclusion list causes an outage.

Choosing between NSX load balancer and Avi

Need NSX load balancer Avi Load Balancer
Supervisor networking models NSX VPC or NSX segment NSX VPC, NSX segment or VLAN
Shared with non-Supervisor workloads No Yes
Requirements Edge cluster with large form factor Edge nodes or bigger 1:1 with NSX Manager; integrated with NSX before Supervisor activation
Entitlement Included in VCF for Supervisor use Separate licence
VPC integration Load balancer in a VPC only for the Supervisor Per-VPC Enable for Avi Load Balancer toggle

Common trap: Attaching an NSX load balancer to a Tier-0 or an Active/Active Tier-1 - it is supported only on a Tier-1 gateway in Active/Standby mode.

Common trap: Deploying Avi after the Supervisor is enabled and expecting the Supervisor to switch to it - the Supervisor defaults to the NSX load balancer if Avi is not integrated before activation.

Get the whole book

This note is one section of Ultra Transcenders 3V0-25.25: Advanced VMware Cloud Foundation 9 Networking, an independent study guide that explains every topic the exam covers by technology, with comparison tables, diagrams and the common traps, plus a glossary linked to Broadcom TechDocs.

Amazon.co.ukKindle: coming soonPaperback: coming soon
Amazon.comKindle: coming soonPaperback: coming soon

Due on Amazon in December 2026, in Kindle and paperback editions.