Veeam ONE offers suppression during known activity, silence mode for maintenance, modelling against history and notification batching to stop alarm storms burying the alerts that matter.

Suppression options

Option Scope When it applies Notes
Silence mode An object, or a container and all its child objects Manually until exited, or on a schedule (once, daily, weekly, monthly) Suppresses all alarms on the object and also Veeam Intelligent Diagnostics log analysis
Veeam Backup activity (alarm Suppress tab) VMs being processed and their hosts and datastores While Veeam Backup & Replication jobs process the VMs vSphere and Hyper-V alarms only; needs a connected backup server
Snapshot creation / deletion (Suppress tab) The object or its parents While the hypervisor creates or deletes a snapshot vSphere alarms only
Suppress alarm based on schedule (Suppress tab) The alarm Weekday time intervals Intervals on the same day must not overlap
Guest disk suppression Selected guest OS disks of a VM Always Only for Guest disk space alarms

For alarm-specific suppression, Veeam ONE shows no notifications and runs no actions while suppressed; if the object is still affected when the suppression period ends, the alarm triggers and its actions run. The Veeam Backup activity option is precise in scope: selected on a VM CPU usage alarm it suppresses only VMs being backed up or replicated, but on a Host CPU usage alarm it suppresses the whole host while any VM on it is being processed.

A silence mode schedule entry can apply to child objects and carry a comment of up to 512 characters. Disabled schedule entries stay listed but are not applied; Exit Silence Mode ends a manual or scheduled period.

Tuning tools

Tool What it does
Alarm modelling Applies current alarm settings to historical data (week, month or year) for chosen objects and forecasts how many alarms of each severity would be raised; started from the main menu Modeling, an object’s Alarms > Modeling, or selected alarms in Alarm Management
Severity tiers Warning and Error rules on the same alarm so only the higher threshold is urgent
Ignore after / Trigger after Event-based rules can fire only after repeated events and stop repeating until resolved
Aggregation type Min with “Above” fires only on sustained breaches
Existing alarm rules with delay An alarm built on another alarm fires a set delay after the source alarm triggers
Other notification policy Groups alarms into a summary email every interval (30 minutes by default)
Notification conditions Errors only on noisy channels; disable resolved and acknowledged emails
Exclusions Remove objects that are expected to breach

Common trap: Relying on “Veeam Backup activity” suppression for Veeam Backup & Replication alarms - it applies to vSphere and Hyper-V alarms only, and only when a backup server is connected; snapshot suppression is vSphere-only.

Get the whole book

This note is one section of Ultra Transcenders VONE-13: Veeam ONE 13, an independent study guide that explains every topic the course covers by technology, with comparison tables, diagrams and the common traps, plus a glossary linked to the Veeam Help Center.

Amazon.co.ukKindle: coming soonPaperback: coming soon
Amazon.comKindle: coming soonPaperback: coming soon

Due on Amazon in January 2027, in Kindle and paperback editions.

About the book · VONE-13 terms in the glossary · All VONE-13 study notes

More VONE-13 study notes