How the two Workload Placement intents differ: utilisation objectives and headroom against tag-based placement.
From Ultra Transcenders 3V0-11.26 by Tony Rough (coming December 2026)
Workload Placement (Capacity > Optimize > Workload Placement tab) rebalances VMs and storage across clusters in a data center or custom data center. It is driven by two separate cards: Operational Intent, which says how clusters should be used, and Business Intent, which says where VMs are allowed to run.
| Operational Intent | Business Intent | |
|---|---|---|
| Question answered | How should utilisation be spread? | Which VMs may run on which clusters or hosts? |
| Configured in | Policy > Workload Automation (Edit on the Operational Intent card opens it) | Edit Business Intent dialog on the Business Intent card |
| Main settings | Utilization objective (Balance, Moderate, Consolidate), cluster headroom, Storage vMotion allowed or not, target network mapping | vCenter tag categories and tag names for Placement, Exclusion tags, cluster-level or host-level placement |
| Permission | Rights to edit the policy | Read and Write on Administration > Configuration > WLP Settings |
| Shows as not optimised when | Workloads are not optimised for the objective | Tag violations exist (the violating tags are listed) |
Operational Intent objectives: Balance spreads load for maximum headroom when performance comes first; Moderate minimises contention; Consolidate packs workloads onto fewer clusters to free resources and possibly cut licence and power costs. Cluster headroom is an extra buffer (for example 20%); a large headroom limits optimisation, and HA overhead is already in usable capacity.
For host-based placement, VCF Operations creates and manages DRS rules itself and deactivates all conflicting user-created VM-VM and VM-Host affinity and anti-affinity rules; you must acknowledge this.
Common trap: Configuring host-level Business Intent while relying on existing DRS affinity rules - VCF Operations deactivates all current and future conflicting user DRS rules and manages its own.
Prerequisites include actions enabled in the vCenter adapter, DRS enabled and fully automated on the clusters, candidate clusters on the same network or port group with shared, datastore cluster or vSAN storage, and moves only within a data center or custom data center. VMs with affinity or anti-affinity rules are not moved. For VCF Automation-managed custom data centers, the Business Intent window is not operational.
This note is one section of Ultra Transcenders 3V0-11.26: Advanced VMware Cloud Foundation 9 Administrator, an independent study guide that explains every topic the exam covers by technology, with comparison tables, diagrams and the common traps, plus a glossary linked to Broadcom TechDocs.
Due on Amazon in December 2026, in Kindle and paperback editions.
About the book · 3V0-11.26 terms in the glossary · All 3V0-11.26 study notes
How the two vSAN architectures differ in devices, network, ready nodes and policy behaviour, and where VCF fixes the choice.
What each vSAN encryption feature protects, where its keys come from, and what enabling it does to an existing cluster.
Minimum hosts and capacity used for each failures-to-tolerate option on vSAN ESA and OSA.
Which data evacuation mode fits which maintenance task, and the risk or limit that comes with each.
What each CPU and memory allocation setting does under contention, and the documented rules for using them.
Which load balancers each Supervisor networking stack supports, and how Foundation, NSX and Avi load balancers compare.
How the two VCF Automation organization types differ in platform, prerequisites and tenancy.
What the Provider Management Portal's Quick Start builds for you, what Manual Setup lets you choose, and when each fits.
Which vSAN cluster provides storage, which consumes it, and what mounting a remote datastore involves.