Which load balancers each Supervisor networking stack supports, and how Foundation, NSX and Avi load balancers compare.
From Ultra Transcenders 3V0-11.26 by Tony Rough (coming December 2026)
Every Supervisor pairs one networking stack with one load balancer, and the pairing limits what else you can do. Start the design by choosing the stack, then the load balancer that the stack allows.
vSphere Supervisor can use the vSphere networking stack (a vSphere Distributed Switch) or NSX. A Supervisor on the vSphere networking stack needs a load balancer on the vCenter management network to give DevOps users and external services access.
| Networking stack | Load balancers supported | Notes |
|---|---|---|
| vSphere networking with VDS | Foundation Load Balancer, Avi Load Balancer | All hosts on the same VDS; distributed port groups act as Workload Networks |
| NSX Segment Networking | NSX Load Balancer, Avi Load Balancer | NCP creates a tier-1 gateway and load balancer per namespace |
| NSX Virtual Private Clouds (VPC) | NSX Load Balancer, Avi Load Balancer | Recommended model in VCF; the supported network stack for VCF Automation |
The design guide compares the three load balancers this way:
| Load balancer | Where it fits | Benefits | Limits |
|---|---|---|---|
| NSX Load Balancer | Default for NSX VPC and NSX segment models; not available for VLAN (VDS) networking | No extra configuration or entitlement; runs on NSX Edges | No Layer 7 application rules; cannot be shared with non-Supervisor workloads; Edges must be at least Large form factor |
| Avi Load Balancer (formerly NSX Advanced Load Balancer) | Add-on for all networking models | Scalable, advanced monitoring, can be shared with other workloads | Additional entitlement, deployment and configuration |
| Foundation Load Balancer (FLB) | VLAN (VDS) networking only | Bundled with vCenter, no extra entitlement, single node or active/standby pair | Layer 4 only, limited scalability |
Avi Load Balancer must be integrated with NSX before the Supervisor is activated. If NSX does not detect an Avi integration, the Supervisor uses the NSX Edge load balancer instead. Avi has a 1:1 relationship with NSX Manager, so when NSX is shared across workload domains only one Avi instance can be integrated, and later workload domains share it.
Conditions for using Avi with NSX:
With Enhanced Linked Mode, only one linked vCenter can be used with the Avi Controller; in a multi-tier tier-0 topology, only one tier-0 gateway can be used. Avi components are the Controller cluster, the Service Engines (vnic0 to management, vnic1 to 8 to data networks, up to 1000 virtual services per Service Engine) and the Avi Kubernetes Operator (AKO), which is installed on the Supervisor at activation. The first Service Engine is created only when the first virtual service is configured.
A Supervisor uses only one load balancer, and a VPC must use the same one as its Supervisor: a Supervisor on the NSX load balancer cannot use a VPC that uses Avi.
Common trap: Deploying Avi after the Supervisor is running and expecting the Supervisor to switch to it - if Avi is not detected at activation, the Supervisor defaults to the NSX load balancer. The Avi design page adds that, when the Supervisor is activated during workload domain creation, Avi must be deployed after the workload domain exists but before the centralised gateway connectivity is configured; the zone-model pages, by contrast, allow activation during workload domain creation only with the NSX load balancer.
This note is one section of Ultra Transcenders 3V0-11.26: Advanced VMware Cloud Foundation 9 Administrator, an independent study guide that explains every topic the exam covers by technology, with comparison tables, diagrams and the common traps, plus a glossary linked to Broadcom TechDocs.
Due on Amazon in December 2026, in Kindle and paperback editions.
About the book · 3V0-11.26 terms in the glossary · All 3V0-11.26 study notes
How the two vSAN architectures differ in devices, network, ready nodes and policy behaviour, and where VCF fixes the choice.
What each vSAN encryption feature protects, where its keys come from, and what enabling it does to an existing cluster.
Minimum hosts and capacity used for each failures-to-tolerate option on vSAN ESA and OSA.
Which data evacuation mode fits which maintenance task, and the risk or limit that comes with each.
What each CPU and memory allocation setting does under contention, and the documented rules for using them.
How the two Workload Placement intents differ: utilisation objectives and headroom against tag-based placement.
How the two VCF Automation organization types differ in platform, prerequisites and tenancy.
What the Provider Management Portal's Quick Start builds for you, what Manual Setup lets you choose, and when each fits.
Which vSAN cluster provides storage, which consumes it, and what mounting a remote datastore involves.