FREE STUDY NOTES · 3V0-11.26

vSAN ESA vs OSA in VCF 9.0 workload domains

How the two vSAN architectures differ in devices, network, ready nodes and policy behaviour, and where VCF fixes the choice.

From Ultra Transcenders 3V0-11.26 by Tony Rough (coming December 2026)

VCF 9.0 deploys both vSAN architectures. The choice is a single checkbox in the wizard, but it is made earlier, when hosts are commissioned, and it drives hardware, network and policy behaviour.

vSAN Express Storage Architecture (ESA) is a single-tier architecture built on NVMe devices only, organised as a storage pool. vSAN Original Storage Architecture (OSA) is a two-tier architecture with a cache tier and a capacity tier in disk groups, and can use SATA, SAS and NVMe devices in all-flash or hybrid combinations. The design guide recommends ESA for high-performance, low-latency workloads, with OSA as the option when newer hardware is not available.

Attribute vSAN ESA vSAN OSA
Tiers Single tier, storage pool Cache tier plus capacity tier, disk groups
Devices NVMe only (certified drives, minimum 1.6 TB per device, up to 24 per node) SATA, SAS, NVMe; flash or magnetic
Minimum device layout Storage pool devices One cache device and at least one capacity device per disk group; at least one disk group per host
Smallest ready node vSAN-ESA-AF-0: 16 cores, 128 GB memory Per vSAN hardware compatibility guide
Network 10 GbE minimum, 25 GbE or higher recommended; only the vSAN-ESA-AF-0 profile supports 10 GbE 10 GbE minimum in VCF (standalone vSAN allows dedicated 1 GbE for hybrid); 25 GbE or higher recommended
Space efficiency Compression set per object through storage policy (default on) Deduplication and compression set at cluster level
Wizard options in VCF vSAN Cluster Type (HCI or Storage), optional Storage Client Network, auto-policy management (fixed) Failures to Tolerate, Space efficiency (deduplication and compression); compute-cluster type when adding a cluster
vSAN storage clusters Supported (requires ESA) Not supported
Witness appliance for stretching vSAN ESA appliance vSAN OSA appliance

Requirements common to both in VCF 9.0:

Host counts

A standard vSAN cluster needs at least three hosts contributing capacity. VCF accepts three nodes for workload domain clusters, but a three-node cluster tolerates one host failure and cannot rebuild objects back to policy compliance. The design guide therefore recommends starting with four nodes: objects rebuild automatically after a failure, Reserved Capacity can be enabled, and ESA auto-policy management can select a capacity-efficient RAID-5 policy. vSAN storage clusters require a minimum of four nodes.

Auto-policy management (ESA)

For an ESA cluster the wizard shows Storage Policy: Auto-policy management, which cannot be modified during deployment. After configuration, vSAN creates and assigns an optimal default datastore policy named ClusterName - Optimal Default Datastore Policy, based on the cluster type (standard or stretched) and host count. With auto-policy management, RAID-5 needs four hosts (ESA RAID-5 itself can run on three) and RAID-6 needs six hosts. Auto-policy management is turned off in the vSphere Client under the cluster’s Configure > vSAN > Services, in the vSAN ESA pane; this is required for multi-rack clusters that use vSAN fault domains, which then need a manually created and assigned default policy.

Common trap: Expecting a four-node vSAN storage cluster with auto-policy management to get RAID-5 - with Host Rebuild Reserve on a four-host storage cluster, auto-policy management prevents the RAID-5 policy. Size such clusters larger, or plan the policy manually.

Common trap: Assuming vSAN ESA will run on any 10 GbE network - 10 GbE is the minimum, but only the vSAN-ESA-AF-0 ready node profile supports it, larger ESA nodes require 25 GbE, and 10 GbE on ESA triggers a vSAN cluster compliance check.

Get the whole book

This note is one section of Ultra Transcenders 3V0-11.26: Advanced VMware Cloud Foundation 9 Administrator, an independent study guide that explains every topic the exam covers by technology, with comparison tables, diagrams and the common traps, plus a glossary linked to Broadcom TechDocs.