How the two vSAN architectures differ in devices, network, ready nodes and policy behaviour, and where VCF fixes the choice.
From Ultra Transcenders 3V0-11.26 by Tony Rough (coming December 2026)
VCF 9.0 deploys both vSAN architectures. The choice is a single checkbox in the wizard, but it is made earlier, when hosts are commissioned, and it drives hardware, network and policy behaviour.
vSAN Express Storage Architecture (ESA) is a single-tier architecture built on NVMe devices only, organised as a storage pool. vSAN Original Storage Architecture (OSA) is a two-tier architecture with a cache tier and a capacity tier in disk groups, and can use SATA, SAS and NVMe devices in all-flash or hybrid combinations. The design guide recommends ESA for high-performance, low-latency workloads, with OSA as the option when newer hardware is not available.
| Attribute | vSAN ESA | vSAN OSA |
|---|---|---|
| Tiers | Single tier, storage pool | Cache tier plus capacity tier, disk groups |
| Devices | NVMe only (certified drives, minimum 1.6 TB per device, up to 24 per node) | SATA, SAS, NVMe; flash or magnetic |
| Minimum device layout | Storage pool devices | One cache device and at least one capacity device per disk group; at least one disk group per host |
| Smallest ready node | vSAN-ESA-AF-0: 16 cores, 128 GB memory | Per vSAN hardware compatibility guide |
| Network | 10 GbE minimum, 25 GbE or higher recommended; only the vSAN-ESA-AF-0 profile supports 10 GbE | 10 GbE minimum in VCF (standalone vSAN allows dedicated 1 GbE for hybrid); 25 GbE or higher recommended |
| Space efficiency | Compression set per object through storage policy (default on) | Deduplication and compression set at cluster level |
| Wizard options in VCF | vSAN Cluster Type (HCI or Storage), optional Storage Client Network, auto-policy management (fixed) | Failures to Tolerate, Space efficiency (deduplication and compression); compute-cluster type when adding a cluster |
| vSAN storage clusters | Supported (requires ESA) | Not supported |
| Witness appliance for stretching | vSAN ESA appliance | vSAN OSA appliance |
Requirements common to both in VCF 9.0:
A standard vSAN cluster needs at least three hosts contributing capacity. VCF accepts three nodes for workload domain clusters, but a three-node cluster tolerates one host failure and cannot rebuild objects back to policy compliance. The design guide therefore recommends starting with four nodes: objects rebuild automatically after a failure, Reserved Capacity can be enabled, and ESA auto-policy management can select a capacity-efficient RAID-5 policy. vSAN storage clusters require a minimum of four nodes.
For an ESA cluster the wizard shows Storage Policy: Auto-policy management, which cannot be modified during deployment. After configuration, vSAN creates and assigns an optimal default datastore policy named ClusterName - Optimal Default Datastore Policy, based on the cluster type (standard or stretched) and host count. With auto-policy management, RAID-5 needs four hosts (ESA RAID-5 itself can run on three) and RAID-6 needs six hosts. Auto-policy management is turned off in the vSphere Client under the cluster’s Configure > vSAN > Services, in the vSAN ESA pane; this is required for multi-rack clusters that use vSAN fault domains, which then need a manually created and assigned default policy.
Common trap: Expecting a four-node vSAN storage cluster with auto-policy management to get RAID-5 - with Host Rebuild Reserve on a four-host storage cluster, auto-policy management prevents the RAID-5 policy. Size such clusters larger, or plan the policy manually.
Common trap: Assuming vSAN ESA will run on any 10 GbE network - 10 GbE is the minimum, but only the vSAN-ESA-AF-0 ready node profile supports it, larger ESA nodes require 25 GbE, and 10 GbE on ESA triggers a vSAN cluster compliance check.
This note is one section of Ultra Transcenders 3V0-11.26: Advanced VMware Cloud Foundation 9 Administrator, an independent study guide that explains every topic the exam covers by technology, with comparison tables, diagrams and the common traps, plus a glossary linked to Broadcom TechDocs.
Due on Amazon in December 2026, in Kindle and paperback editions.
About the book · 3V0-11.26 terms in the glossary · All 3V0-11.26 study notes
What each vSAN encryption feature protects, where its keys come from, and what enabling it does to an existing cluster.
Minimum hosts and capacity used for each failures-to-tolerate option on vSAN ESA and OSA.
Which data evacuation mode fits which maintenance task, and the risk or limit that comes with each.
What each CPU and memory allocation setting does under contention, and the documented rules for using them.
Which load balancers each Supervisor networking stack supports, and how Foundation, NSX and Avi load balancers compare.
How the two Workload Placement intents differ: utilisation objectives and headroom against tag-based placement.
How the two VCF Automation organization types differ in platform, prerequisites and tenancy.
What the Provider Management Portal's Quick Start builds for you, what Manual Setup lets you choose, and when each fits.
Which vSAN cluster provides storage, which consumes it, and what mounting a remote datastore involves.