The four starting points, the path and tool each one leads to, and which existing components converge into VCF 9.0.
From Ultra Transcenders 2V0-15.25 by Tony Rough
The first diagnostic question is which workflow the environment should be on. Using the wrong path produces failures that no amount of retrying fixes. Figure 4.1 shows the four starting points and the path and tool each one leads to.
| Starting point | Path | Tool |
|---|---|---|
| Nothing to reuse | Deploy a new VCF fleet or instance | VCF Installer |
| Existing VCF 5.x instance | Upgrade the management domain, then workload domains | SDDC Manager UI, then VCF Operations (Chapter 3, “Upgrading VCF 5.x to VCF 9.0”) |
| Existing vSphere (vCenter and ESX), with or without Aria products, not part of VCF | Converge into the management domain of a new VCF fleet or a new VCF instance in an existing fleet | VCF Installer |
| Further existing vCenter instances, with or without NSX | Import as workload domains into an existing VCF instance | VCF Operations |
Points to keep in view:
The VCF Installer documentation describes the components converged or upgraded as follows:
| Component | Converged to VCF 9.0.x |
|---|---|
| Aria Suite Lifecycle | Not upgraded: a VCF Operations fleet management appliance 9 is deployed and the existing connections are imported |
| Aria Operations / VCF Operations | Yes, automated or manual |
| Aria Automation / VCF Automation | Yes |
| VMware Identity Manager / VCF Identity Broker | No: deploy VCF Identity Broker manually |
| Aria Automation Orchestrator, Aria Operations for Networks | Yes |
| HCX | Listed as Yes, but the VCF Installer known issues state that an existing vCenter with VMware HCX deployed is not supported (no workaround) |
| Aria Operations for Logs / VCF Operations for logs | No: redeploy 9.0 |
| SDDC Manager | Not applicable (deployed new) |
| NSX | VCF 9.0.0: no (a new NSX 9.0 is deployed); VCF 9.0.1: yes, without ELM |
| vCenter, ESX, vSAN | Yes |
Common trap: Trying to converge a workload-domain vCenter with the VCF Installer - converge builds the management domain only; additional vCenter instances are imported as workload domains from VCF Operations.
Common trap: Running the convergence path on an existing VCF 5.x instance - a VCF 5.x instance is upgraded through SDDC Manager, not converged; convergence is for vSphere environments that are not yet part of VCF.
This note is one section of Ultra Transcenders 2V0-15.25: VMware Cloud Foundation 9.0 Support, an independent study guide that explains every topic the exam covers by technology, with comparison tables, diagrams and the common traps, plus a glossary linked to Broadcom TechDocs.
Free to read with Kindle Unlimited. Opens Amazon in a new tab.
About the book · 2V0-15.25 terms in the glossary · All 2V0-15.25 study notes
Which log on which appliance records the failed step, from domainmanager.log and lcm-debug.log to hostd, vpxa and the NSX logs.
The two replacement paths side by side, the import rules for external certificates and the documented replacement failures.
What each state means, how hostd, vpxa and FDM fit in, and the first action for a host that is not responding.
What Agent Unreachable, Uninitialized, Host Failed, Network Partitioned and Network Isolated mean, and the documented fix for each.
Absent and degraded compared, object accessibility rules and how vSAN behaves when a device, controller or host fails.
The channels between NSX Manager and a host, and the symptom, cause and fix for preparation and connection faults.
Bulk, Cold, vMotion, Replication Assisted vMotion and OS Assisted Migration compared, and the VM attributes that block each one.